CN

×

keywords:

xxxx1 xxx2 xxx3 xx4 copy
Shenzhen Meiyad Optoelectronics Co., Ltd. Shenzhen Meiyad Optoelectronics Co., Ltd.

News

Meiyad Held An Excellent Employee Recognition Ceremony

03
07
2024

On July 1st afternoon, Shenzhen Meiyad Optoelectronics Co., Ltd. held a commendation ceremony for outstanding employees. The gradual improvement in Meyad's performance in recent years owes much to the efforts of every employee. In this rapidly changing era, their persistence, innovation, commitment to quality, and excellence have helped the company maintain a leading position in the competitive market. Through their outstanding performance and contributions, they have surpassed themselves.


Meiyad Held An Excellent Employee Recognition Ceremony


Sales Champion - Jian Minmin


The company's performance improvement is inseparable from the hard work and unremitting efforts of the sales team. Among them, the sales champion Jian Minmin stood out with her outstanding performance. Her professional ability and tenacity won the trust of customers and brought remarkable sales results to the company. The general manager presented medals and prizes to the sales champion-Jian Minmin.


Sales Champion - Jian Minmin


Excellent Employees


In the big family of Meiyad, there is a group of people who have become an important driving force for the company's sustainable development with their outstanding work performance and selfless dedication. They are the pride of the team and the company's outstanding employees. Their stories and achievements inspire every colleague.


Excellent employees of the sales department and department leaders


Excellent employees of the sales department and department leaders


Excellent employees of the back office department and department leaders


Excellent employees of the back office department and department leaders


Excellent employees of the manufacturing department and department leaders


Excellent employees of the manufacturing department and department leaders


Excellent Management Team


Excellent Management Team


Under the guidance of the general manager, Meiyad has an excellent management team. They closely follow the company's strategic blueprint to ensure the efficient execution of various tasks, while focusing on team building and talent training. Through their unremitting efforts, they not only promote the smooth progress of daily operations, but also provide lasting motivation and a solid foundation for the long-term development of the company. The leadership, execution and innovation of this management team are one of the key factors for Meiyad' continuous success.

You May Also Like

Outdoor LED Display Installation Guide | GE500 Series by Meiyad

14|07|2026

Outdoor LED Display Installation Guide: A Complete Guide to GE500 Series

Installing an outdoor LED display requires more than simply mounting LED cabinets together. A professional installation process directly affects the display’s stability, visual performance, waterproof reliability, and long-term service life.From steel structure preparation and cabinet alignment to electrical testing and maintenance planning, every step plays an important role in ensuring reliable operation in outdoor environments.The GE500 Series outdoor LED display by Meiyad is designed to deliver installation efficiency and long-term performance. Featuring an aluminum profile cabinet design, excellent heat dissipation, multiple pixel pitch options, energy-saving design, and flexible maintenance features, GE500 provides a reliable solution for commercial outdoor display applications.This guide explains the key steps and considerations for outdoor LED display installation, helping installers and project teams better understand the GE500 structure, preparation requirements, and installation process.Safety TipsWarning! Before installing, powering on, operating, or debugging this product, carefully read the safety precautions provided in this section.Warning NoticeEnsuring Safety - Please carefully read and adhere to the following safety instructions:The equipment complies with the standard GB4943.1-2022.The equipment is safe for use in regions at altitudes below 5000 meters.The plug serves as a disconnecting device. The socket-outlet should be installed near the equipment and must be easily accessible.Do not place exposed ignition sources, such as lit candles, on the equipment.Do not use the product in high-temperature or high-humidity environments. Use the product in low-dust areas and avoid direct exposure to sunlight.Do not attempt to modify, repair, or disassemble the product on your own. Improper handling may lead to short circuits, product damage, or even fire. Unauthorized modifications will void the product's warranty.GE500 Product Overview: Designed for Outdoor LED Display ApplicationsExcellent Heat DissipationAluminum profile cabinet and aluminum module chassis provide excellent heat dissipation performance. Contact-type thermal conductive silicone pads improve heat transfer efficiency and accelerate heat dissipation.Aluminum profile heat dissipation is 2× better than die-cast aluminum, Die-cast aluminum is 2× better than sheet metal cabinets.Energy SavingSaves 35% energy compared to conventional screens. Reduces operating costs while maintaining excellent display performance. Supports green and low-carbon applications.Front & Rear Maintenance DesignEasy operation fast installation and maintenance, truly saves time, labor, and effort.Waterproof & DustproofDesigned with waterproof and dust proof structure. Protection level: Front & Rear IP65+. Resistant to rain, wind and dust, suitable for outdoor environments.The series is suitable for applications such as:Outdoor advertising displaysCommercial building facadesPublic information screensLarge-scale digital signage projectsGE500 Technical Parameters You Should Know Before InstallationModelP2.97P3.91P4.81P6.25P7.81P10.42Pixel Pitch (mm)2.973.914.816.257.8110.42Module Size (mm)500*250Module Resolution (dot)168*84128*64104*5280*4064*3248*24Pixel ConfigurationSMD1415SMD1921SMD1921SMD2727SMD2727SMD2727Scan Mode(s)1/211/161/131/51/41/2Refresh Rate (Hz)≥3840Gray Scale (bit)14Brightness (nits)≥4500≥4500≥4500≥6000≥6000≥6000Viewing Angle (°)140/140Cabinet Size (mm)1000*1000*75Cabinet Weight (kg)25Cabinet Resolution (dot)336*336256*256208*208160*160128*12896*96Ingress Protection (IP) RatingIP65Input Voltage110-220V; AC +10%Maintenance MethodFront and rear maintenanceNote:Product images are for reference only. The actual product (including but not limited to appearance, color, and dimensions) may vary slightly. Please refer to the product as specified in the actual order drawings.The specifications and parameters provided in this document are reference values. Some data are obtained from tests conducted in Meiyad's internal laboratory under specific conditions. Actual performance may vary due to differences in product batches, configurations, controller versions, and usage environments.Product Installation PrecautionsWarning: Before installing the steel structure, clearly mark the safety zone and cordon it off. Safety first! Please be sure to read, understand, and comply with all safety instructions.The construction site must implement all necessary safety measures, including the proper use of hard hats, safety harnesses, and safety nets. At the same time, temporary electrical usage regulations must be strictly followed.Precautions for Unpacking and Inspection1) Unpacking and Removing the Display ScreenStep 1: Open the top cover of the wooden case and remove the cabinet.Step 2: Remove the anti-static/moisture-proof plastic bag.Step 3: Open the rear cover of the cabinet and check whether all screws, cables, and power cords are loose or detached.Step 4: Inspect the cabinet for any deformation or damage caused during transportation.2) Installation PrecautionsA: When removing the display cabinet from the wooden case, handle it with care. Ensure a protective layer (e.g., paper or carpet) is laid on the ground to avoid collisions with the display lamp surface during.B: During installation, do not use iron tools/hammers to strike the cabinet or employ rough methods such as kicking.C: If the gap between cabinets is too large during installation, use a hard object to pad and ensure parallelism and verticality (note: the gap between cabinets should be less than 0.1mm).Power Supply System TestNote: (The inspection of the power supply in the distribution cabinet and the cabinet power supply must be performed by qualified electricians.)A. Check for short circuits between the Live (L) wire, Neutral (N) wire, and Ground (FG) wire.B. Check for short circuits between the Neutral (N) wire and the Ground (FG) wire. The resistance value should be ∞.C. Check for short circuits between the receiving card +4.2V power supply and GND (30–50Ω) terminals, Ground (FG) wire, Live (L) wire, and Neutral (N) wire. The resistance value should be ∞.D. Check for short circuits between the receiving board GND, Ground (FG) wire, Live (L) wire, and Neutral (N) wire. The resistance value should be ∞.E. Test for short circuits between the +4.2V output and GND of each power supply. The resistance value should be 30–50Ω.LED Display Installation PrecautionsA. After installation, the display screen must be equipped with lightning protection. A surge protector must be installed at the main power input terminal.B. Never perform live operations on the display screen.C. During the fixation of cabinets, ensure they are securely fastened while avoiding collisions that may cause damage to the product.D. Workers must adopt safety measures during installation (e.g., wearing protective helmets, safety harnesses, etc.).E. When removing control system boards or other equipment, take anti-static precautions (e.g., wearing anti-static gloves).Installation InstructionsA. This product is designed for outdoor use. Store it properly before installation.B. To ensure safety, the product must be installed by professional technicians.C. Before installation, disconnect the power supply and check whether the insulation layer of the power cord is intact.D. Ensure the reliability of the product and the installation structure. Verify that the structure is stable and secure before installation to avoid potential safety hazards.E. During installation, prioritize safety. Ensure the bracket is stable and the installers are safe to prevent potential risks.F. Grounding must be installed to ensure the safety of personnel and equipment.G. Only professional technicians are allowed to perform repairs on this product.Core Points of Cabinet Installation1. Structural Stability and FlatnessA. Benchmark Positioning: First, determine the center point and reference lines of the display screen. Install the cabinets starting from the center and moving outward to ensure overall symmetry.B. Layer-by-Layer Installation: It is recommended to install the cabinets from bottom to top, layer by layer. After completing each layer, check its levelness and alignment with the steel structure.C. Leveling Tools:Use high-precision tools such as magnetic-mounted laser levels to monitor the flatness of the cabinet surface in real time during installation. Avoid relying solely on visual inspection.D. Even Force Distribution:When tightening the cabinet connection screws, adopt the "diagonal tightening" method. Tighten the screws gradually and in multiple stages to ensure even force distribution between the cabinets and the steel structure, as well as between adjacent cabinets. This prevents deformation caused by excessive stress at any single point.Warning: The horizontal and vertical flatness of each cabinet / each layer must be properly adjusted before proceeding to the next step. Poor cabinet flatness may result in noticeable "dark lines" or "bright lines" (gaps) between display modules, severely affecting viewing quality and making subsequent adjustments difficult.2. Waterproof Sealing TreatmentA. Waterproof Gaskets: After the complete installation or maintenance of the screen, inspect the waterproof gaskets on the rear cover of the cabinets for detachment or deformation. If any abnormalities are found, replace the gaskets promptly to prevent internal water damage to the display.B. Backside Waterproofing: For displays with maintenance access at the back or wall-mounted displays, all maintenance doors and decorative structures must be sealed and waterproofed to prevent long-term corrosion of the screen structure or cabinets by rainwater.3. Heat Dissipation and Ventilation AssuranceA. Ventilation Pathways: During installation, ensure that the air intake and exhaust vents designed on the back of the cabinets are not blocked. Maintain clear and unobstructed cooling air channels.B. Cooling Measures: If the display design includes a backside ventilation pathway, ensure air convection within the channel. Avoid installing the cabinets directly against airtight walls, and leave sufficient space for heat dissipation. Depending on the ambient temperature, additional convection fans or air conditioning may be installed to enhance cooling.Post-Installation Inspection and TestingWarning: After the installation of the display screen is completed and all cables are connected, a comprehensive cable test and inspection must be performed before powering on the system.A. Physical Structure Re-inspection: After the installation of the steel structure and cabinets, recheck all screws to ensure they are properly tightened and verify the stability of all welding points.。B. Waterproofing Review: Carefully inspect all sealed areas to ensure the application is complete, with no missed or interrupted sections.。C. Insulation and Short Circuit Test: Use a multimeter to measure the power input terminals and ensure no short circuits are present.。D. Power-On Test: After supplying power, check whether the cabinet power supply is functioning normally and confirm that all power indicators are lit. (This must be done immediately after powering on to promptly identify any abnormal circuits and prevent potential equipment damage.)E. Troubleshooting: After debugging, display white, red, green, and blue colors on the LED screen to test for any damaged or malfunctioning modules. Replace or repair faulty modules as necessary.Installation Accessories and ToolsGE500 Cabinet / Module IntroductionProduct DimensionsThe GE500 cabinet measures 1000mm in width, 1000mm in height, and approximately 99mm in thickness.The module kit is manufactured using die-cast aluminum integrated molding, with dimensions of 500mm in width, 250mm in height, and 24.15mm in thickness.Each cabinet is arranged with 2 modules in width and 4 modules in height, totaling 8 modules to form a complete cabinet unit.Cabinet / Module Function IntroductionRear View of CabinetCabinet Exploded ViewRear View of ModuleFront View of ModuleStep-by-Step GE500 Outdoor LED Display Installation ProcessSteel Structure InstallationWarning: Before installing the steel structure, clearly mark the safety zone and cordon it off. Safety first! Please be sure to read, understand, and comply with all safety instructions.The construction site must implement all necessary safety measures, including the proper use of hard hats, safety harnesses, safety nets, fire extinguishers, fire blankets, etc. At the same time, temporary electrical usage regulations must be strictly followed.The GE500 series products support both front and rear installation methods, with some structural and accessory variations.The GE500 series is typically applied in front-installation wall-mounted setups. Meiyadi can provide customers with steel structure installation drawings.1. Site SurveyThe pre-sales engineer assesses the installation environment to determine the installation method, screen steel structure dimensions, and fixation approach.2. Data Compilation & Drawing PreparationCollate on-site measurement data and customer/user requirements, and provide them to the pre-sales engineer for generating steel structure drawings.3. Steel Structure FabricationFabricate and weld the steel structure according to the drawings, using embedded steel plates for integration.4. Steel Structure FixationSecure the steel structure to the wall using embedded steel plates or expansion bolts as specified in the drawings.5. Dimensional VerificationAfter steel structure installation, use a level or measuring tape to verify dimensions and positioning. Confirm accuracy before proceeding with cabinet installation.Important Notice:The drawings provided by our authorized engineers are for reference only if they have not conducted an on-site survey. Installation personnel must determine the appropriate types and quantities of fixing components based on the actual installation environment.Cabinet Installation (Front Installation Method)1. First Layer Cabinet Installation: Start from the center of the screen to install the first cabinet.2. Install cabinets incrementally to the left and right, using cabinet quick locks to secure the cabinets. Simultaneously, adjust the horizontal and vertical alignment at the junction of the two cabinets.Use cabinet connecting plates and bolts ①② to secure the two cabinets to the structure. (Place the connecting plate on the back of the square tube aligned with the holes, then insert the bolts from the front of the cabinet and tighten them into the connecting plate to lock the cabinets in place.)Conclusion: Professional Installation Ensures Long-Term GE500 PerformanceInstalling an outdoor LED display requires careful planning, accurate assembly, and professional testing.From product preparation and cabinet installation to waterproof protection and final inspection, every step contributes to the reliability of the finished display system.With its lightweight cabinet structure, modular design, efficient heat dissipation, and maintenance-friendly features, the GE500 Series by Meiyad provides an installation-efficient solution for outdoor commercial LED display applications.By following professional installation procedures, businesses and project teams can maximize display performance, reduce maintenance challenges, and ensure stable operation throughout the product lifecycle.

Four-Sided Immersive LED Installation at FM Global Centre, Singapore

06|07|2026

Four-Sided Immersive LED Installation at FM Global Centre, Singapore

Meiyad has delivered a four-sided immersive LED display project for FM Global Centre in Singapore, creating a fully integrated digital environment through P1.8 XC COB LED screen technology.The installation is composed of front, left, right, and ceiling LED surfaces, forming a complete spatial visual system that enhances architectural depth and digital interaction.The front screen measures 6600*3037.5 mm, serving as the main visual focus of the space. The left and right screens, each sized at 3000*3075.5 mm, extend the visual continuity on both sides. The ceiling screen measures 5400*2362.5 mm, completing the top enclosure and strengthening the immersive experience.Built with XC 1.8 COB LED panels, the system ensures stable performance, precise image expression, and reliable operation for long-term use in high-end commercial environments.This project demonstrates Meiyad’s capability in delivering complex multi-surface LED solutions that combine structural precision with immersive visual design, redefining how digital content integrates with architectural space.

Send Your Inquiry Today

Factory Direct LED Screen - Fast Quote, Best Price!

Please enter your company name
Please accept the data protection information

I have read and understood the  data protection   information.